HEAD OFFICE: TEL:886-4-2406-8999    FAX:886-4-2406-2617

Proportional Balance Valves (Pilot Operated Reducing/Relieving Valves) EVGR-10

Features

  • Pilot-operated, reducing/relieving valve, which can be infinitely adjusted across a prescribed range using a variable electric input.
  • Pressure output is proportional to DC current or voltage input.
  • This item blocks flow from ② to ① until sufficient pressure is present at ① to open the pilot section by offsetting the electrically induced solenoid force.
  • Increasing electric current or voltage will increase the control (reduced) pressureat ①. Port ③ is typically connected to the reservoir.
  • If external load increases the pressure at ① beyond this setting ,pressure is relieved by allowing flow from ① to ③.

Inquiry
PDF
  • Specifications
  • How to Order
Model Number Maximum Pressure (bar) Maximum Flow (lpm) Rated Current (mA) Voltage (VDC) Weight (kg)
EVGR-10 350 (5076 psi) 60 (15.85 gpm) 1700±10% 12 0.35 (0.77 lbs)
850±10% 24
Fluid Type ISO VG 32, 46, 68
Viscosity (cSt) 10~400 (59~1854 SSU)
Operating Temperature (°C) -30~100 (-22~212°F)
Contamination Level ISO4406. 20/18/15 NAS1638. 9