HEAD OFFICE: TEL:886-4-2406-8999    FAX:886-4-2406-2617

Flow Control Valves VIFC-12

Features

  • Cartridge-style, fixed orifice ,pressure-compensated, hydraulic flow regulating valve. The maintains a constant flow rate out of 2 regardless of load pressure changes in the circuit downstream of 2. The valve begins to respond to load changes when the flow through the valve creates a pressure differential across the control orifice greater than 6.5 bar(95 psi). Reverse flow(2 to 1)returns through the control orifice and is non-compensated.

Inquiry
PDF
  • Specifications
  • How to Order
Model Number Operating Pressure (bar) Flow Settings (lpm) Weight (kg)
VIFC-12 240 (3481 psi) 0.4 ~ 55  (0.11 ~ 14.53 gpm) 0.27 (0.6 lbs)
Fluid Type ISO VG 32, 46, 68
Viscosity  (cSt) 10~400 (59~1854 SSU)
Operating Temperature  (°C) -30~100 (-22~212 °F)
Contamination Level ISO4406. 20/18/15    NAS1638. 9