HEAD OFFICE: TEL:886-4-2406-8999    FAX:886-4-2406-2617

Pressure Control Valves VRQ-02

Features

  • Kick-down relief cartridges act similar to a circuit breaker in an electrical system. The valves will kick completely open and remain open once the pressure at the port 1 (inlet) exceeds the valve setting, creating an unrestricted flow path from port 1 to port 2 (tank). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, flow from port 1 to port 2 must cease and pressure at port 2 must be equal to or greater than the pressure at port 1.
  • Not suitable for use in load holding applications. Intended for use on the actuator side of the system as flow t through the valve must cease for the valve to reset.
  • If used on the pump side of a system, pump flow must be shut off for the valve to reset.

Inquiry
PDF
  • Specifications
  • How to Order
Model Number Maximum Pressure Maximum Flow Weight
VRQ-02 350 (5076 psi) 95 (25.10 gpm) 0.15 (0.33 lbs)
Fluid Type ISO VG 32, 46, 68
Viscosity 10~400 (59~1854 SSU)
Operating Temperature -30~100 (-22~212oF)
Contamination Level ISO4406. 21/19/16 NAS1638,10