HEAD OFFICE: TEL:886-4-2406-8999    FAX:886-4-2406-2617

Flow Control Valves VFX-01

Features

  • Fixed-orifice, pressure-compensated flow controls provide precise flow regulation for meter-in or meter-out applications where there may be wide pressure fluctuations. The flow setting is specified by the user and is set at the factory.
  • Accurate pressure compensated control requires that a 200 psi minimum pressure differential be maintained across the valve.

Inquiry
PDF
  • Specifications
  • How to Order
Model Number Maximum Pressure (bar)  Flow (lpm) Weight (kg)
VFX-01 350 (5076 psi) 0.4~12 (0.11~3.17 gpm) 0.16 (0.35 Ibs)
Fluid Type ISO VG 32, 46, 68
Viscosity (cSt) 10~400 (59~1854 SSU)
Operating Temperature (°C) -30~100 (-22~212°F)
Contamination Level ISO4406. 20/18/15    NAS1638. 9