Flow Control Valves VF-16H
- Home
- Products
- Cartridge Valves
- Flow Control
- Flow Control Valves
Features
- Cartridge-style, pressure-compensted, non-adjustable flow regulator, intended for use in fixed displacement hydraulic circuits requiring partial pump flow diversion on a priority basis.
- Delivering the pump flow to 3 first , then bypassing excess to 2 .The VF-16H maintains a constant flow rate from 3 regardless of load pressure changes in the system downstream of 3 ,or in the bypass leg at 2.
- The valve's spool maintains a constant differential pressure of 6.5 bar(95 psi)across a fixed internal orifice.
- Specifications
- How to Order
Model Number | Operating Pressure (bar) | Flow (lpm) | Priority Flow Setting Range (lpm) | Weight (kg) |
---|---|---|---|---|
VF-16H | 250 (3626 psi) | 190 (50.19 gpm) | 4~113 (1.06~29.85 gpm) | 0.58 (1.27 lbs) |
Fluid Type | ISO VG 32, 46, 68 | |||
Viscosity (cSt) | 10~400 (59~1854 SSU) | |||
Operating Temperature (°C) | -30~100 (-22~212°F) | |||
Contamination Level | ISO4406. 20/18/15 NAS1638. 9 |