HEAD OFFICE: TEL:886-4-2406-8999    FAX:886-4-2406-2617

Directional Valves VSHL-10

Features

  • A spool-type, closed in neutral, spring centered, 2-position, 3-way hot oil shuttle valve, which may be used on hydrostatic transmissions to direct charge pump oil to a heat exchanger or to tank.
  • With internal piloting at port 1, 2 or 4, the valve will direct oil from the port opposite of the piloted port to port 3, thus removing oil from the low-pressure side for cooling or filtration purposes.
  • The valve has a spring-centered spool, and is closed in neutral position.

Inquiry
PDF
  • Specifications
  • How to Order
Model Number Operating Pressure (bar) Bias Spring (bar) Flow (lpm) Weight (kg)
VSHL-10 350 (5076 psi) 4.1 (59 psi) 46 (12.15 gpm) 0.13 (0.29 lbs)
Fluid Type ISO VG 32, 46, 68
Viscosity (cSt) 10~400 (59~1854 SSU)
Operating Temperature (°C) -30~100 (-22~212 °F)
Contamination Level ISO4406. 20/18/15 NAS1638. 9